Fault Diagnostics of Solenoid Valve in Oxygen Injection System

Authors

  • Vaishali Vinayaga, A. L. Amutha, Jackulin Mahariba A.

Keywords:

Fault identification, Life support system, MATLAB, Oxygen Injection System, Solenoid valve

Abstract

The life support system within a submarine ensures crew safety and sustenance during underwater missions. The Oxygen Injection System within the Life support system is crucial for supplying breathable air to the crew through various oxygen valves. The working of a two way internally piloted solenoid valve is checked to provide the right amount of oxygen to the crew. The solenoid valve works on the principle of electromagnetism and hence the opening & closing of these valves are set to be checked using a multimeter which detects the voltage/current supply provided to the valve. Also, a pressure gauge is introduced on both sides of the valves to detect the in/out flow of pressure which identifies the leakage in oxygen valves by monitoring the two-way internally piloted solenoid valves in the Oxygen injection system. This is implemented through MATLAB Simulink and Python for various time intervals in the operational range by displaying the fault condition and statement.

Downloads

Download data is not yet available.

References

H. Guo, K. Wang, H. Cui, A. Xu and J. Jiang, "A Novel Method of Fault Detection for Solenoid Valves Based on Vibration Signal Measurement," 2016 IEEE International Conference on Internet of Things (iThings) and IEEE Green Computing and Communications (GreenCom) and IEEE Cyber, Physical and Social Computing (CPSCom) and IEEE Smart Data (SmartData), Chengdu, China, 2016, pp. 870-873, doi: 10.1109/iThings- GreenCom-CPSCom-SmartData.2016.179.

Wenhao Guo1 , Jinjun Cheng1 , Yangbo Tan1 and Qiang Liu1Published under licence by IOP Publishing Ltd IOP Conference Series: Earth and Environmental Science, Volume 170, Issue 4Citation Wenhao Guo et al 2018 IOP Conf. Ser.: Earth Environ. Sci. 170 042134DOI 10.1088/1755-1315/170/4/042134

Jo, Soo-Ho & Seo, Boseong & Oh, Hyunseok & Youn, Byeng Dong & Lee, Dongki. (2020). Model-Based Fault Detection Method for Coil Burnout in Solenoid Valves Subjected to

Dynamic Thermal Loading. IEEE Access. 8. 77387-70400. 10.1109/ACCESS.2020.2986537.

Fault State Detection in Solenoid Operated Valve based on Convolutional Neural Network using Coil Current Signature Utah Michael Ngbede, Adebena Oluwasegun, M.J. Choi, J.C. Jung* KEPCO International Nuclear Graduate School (KINGS), 658- 91 Haemaji-ro, Seosaeng-myeon, Ulju-gun, Ulsan, 45014 Republic of Korea.

Vassilios A. Tsachouridis, for correspondence, Nikos G. Tsagarakis, D. O. Caldwell, & Brain Robotics. (2011). Sampled Data Control of a Compliant Actuated Joint Using On/Off Solenoid Valves. Journal of Engineering Science and Technology Review, 4(1), 14–24. doi:10.25103/jestr.041.02

Citation Stoyan Stoyanov and Veselin Mihaylov 2020 IOP Conf. Ser.: Mater. Sci. Eng. 1002 012033DOI 10.1088/1757- 899X/1002/1/012033

Said Amrane, Abdallah Zahidi, Mostafa Abouricha, Nawfel Azami, Naoual Nasser, & M. Errai. (2021). Machine Learning for Monitoring of the Solenoid Valves Coil Resistance Based on Optical Fiber Squeezer. Journal Européen Des Systèmes Automatisés, 54(5), 763–767. doi:10.18280/jesa.540511

A Method for Improving Position Control Performances of a Pneumatic Cylinder Using On-Off Solenoid Valves. (2022). Jst: Smart Systems and Devices, 32(1), 34– 41. doi:10.51316/jst.155.ssad.2022.32.1.5

Ying Yu, S. D. Ke, & K D Jin. (2020). Structural Parameters Optimization for a Proportional Solenoid. International Journal of Simulation Modelling. doi:10.2507/ijsimm19-4-co18

Research on Solenoid Valve Fault Diagnosis Algorithm Based on Coil Current

TY - JOUR AU - Yoo, Seungjin AU - Jung, Joon AU - Lee, Jai-Kyung AU - Shin, Sang AU - Jang, Dal PY - 2023/08/18 SP - 7249 T1 - A Convolutional Autoencoder Based Fault Diagnosis Method for a Hydraulic Solenoid Valve Considering Unknown Faults VL - 23 DO - 10.3390/s23167249 JO - Sensors

J. Li, M. Xiao, Y. Sun, G. Nie, Y. Chen and X. Tang, "Failure Mechanism Study of Direct Action Solenoid Valve Based on Thermal-Structure Finite Element Model," in IEEE Access, vol. 8,

pp. 58357-58368, 2020, doi: 10.1109/ACCESS.2020.2982941.

B. Seo, S.-H. Jo, H. Oh, and B. D. Youn, “Solenoid Valve Diagnosis for Railway Braking Systems with Embedded Sensor Signals and Physical Interpretation”, PHM_CONF, vol. 8, no. 1, Oct. 2016.

Auzmendi JA, Moffatt L. Increasing the reliability of solution exchanges by monitoring solenoid valve actuation. J Neurosci Methods. 2010 Jan 15;185(2):280- 3. doi:

1016/j.jneumeth.2009.10.002. Epub 2009 Oct 14. PMID:

Torsten Brune, Rolf Isermann,Model and Signal Based Fault Detection for On/Off Solenoid Valves,IFAC Proceedings Volumes,Volume 33, Issue 11,2000,Pages 423-428,ISSN 1474-

,https://doi.org/10.1016/S1474- 6670(17)37395-0.

Kyoungkwan Ahn, Shinichi Yokota,Intelligent switching control of pneumatic actuator using on/off solenoid

valves,Mechatronics,Volume 15, Issue 6,2005,Pages 683-

,ISSN 0957-

,https://doi.org/10.1016/j.mechatronics.2005.01.001.

Victor Vantilborgh, Tom Lefebvre, Kerem Eryilmaz, & Guillaume Crevecoeur. (2023). Data-Driven Virtual Sensing for Probabilistic Condition Monitoring of Solenoid Valves. Ieee Transactions on Automation Science and Engineering, (99), 1–15. doi:10.1109/tase.2023.3287598.

Citation Stoyan Stoyanov and Veselin Mihaylov 2020 IOP Conf. Ser.: Mater. Sci. Eng. 1002 012033DOI 10.1088/1757- 899X/1002/1/012033

Ching-hai Yang, Sunao Kawai, Yukio Kawakami, Kenji Sinozaki, & Tadahiro Machiyama. (1996). EXPERIMENTAL STUDY ON SOLENOID VALVES CONTROLLED

PNEUMATIC DIAPHRAGM MOTOR. proceedings of the jfps international symposium on fluid power, 1996(3), 247–252. doi:10.5739/isfp.1996.247

Daling Yue, Linfei Li, Liejiang Wei, Zengguang Liu, Chao Liu, & Xiukun Zuo. (2021). Effects of Pulse Voltage Duration on Open–Close Dynamic Characteristics of Solenoid Screw-In Cartridge Valves. Processes, 9(10), 1722–1722. doi:10.3390/pr9101722

Flaviu Nicolae Kesucz. (2020). Theoretical and Experimental Aspects of Signal Analysis Applied to Solenoid-Type Actuators Used in Gas Valves. Carpathian Journal of Electronic and Computer Engineering, 13(1), 13–22. doi:10.2478/cjece-2020-

Hao Tian, & Yu-Ren Zhao. (2018). Coil Inductance Model Based Solenoid on–off Valve Spool Displacement Sensing via Laser Calibration. Sensors, 18(12), 4492–4492. doi:10.3390/s18124492

Ma, D.; Liu, Z.; Gao, Q.; Huang, T. Fault Diagnosis of a Solenoid Valve Based on Multi-Feature Fusion. Appl. Sci. 2022, 12, 5904.

Heitor V. Mercaldi, Elmer A.G. Peñaloza, Rafael A. Mariano, Vilma A. Oliveira, Paulo E. Cruvinel,

Flow and Pressure Regulation for Agricultural Sprayers Using Solenoid Valves**This work was supported by the CNPq under grant 306.477/2013-0 and the Empresa Brasileira de Pesquisa Agropecuária (Embrapa Instrumentação) under Project MP2 No. 02.11.07.0.25.00.00, IFAC-PapersOnLine, Volume 50, Issue 1,

, Pages 6607-

,ISSN24058963,https://doi.org/10.1016/j.ifacol.2017.08.693.

Jameson, N. J., Azarian, M. H., & Pecht, M. (2014). Fault diagnostic opportunities for solenoid operated valves using physics-of-failure analysis. 2014 International Conference on Prognostics and Health Management. doi:10.1109/icphm.2014.7036385

Fengguo Liu, Shihua Cao, Wenlei Zhou, Dongfang Zhao, Longfeng Zheng, Meng Shao,Transient flow analysis on opening process of pneumatic gas proportional valve with two-solenoid valve, Flow Measurement and Instrumentation,Volume 89,2023,102291,ISSN 0955-5986,

https://doi.org/10.1016/j.flowmeasinst.2022.102291

Downloads

Published

12.06.2024

How to Cite

Vaishali Vinayaga. (2024). Fault Diagnostics of Solenoid Valve in Oxygen Injection System. International Journal of Intelligent Systems and Applications in Engineering, 12(4), 1458–1464. Retrieved from https://www.ijisae.org/index.php/IJISAE/article/view/6438

Issue

Section

Research Article